We can now create an Excel spreadsheet to perform these calculations.

Standard fiberglass (FRP) or plastics like PVC will melt. Your spreadsheet should flag temperatures and recommend High-Temperature FRP , Hastelloy , or a brick-lined quench section.

Wet Scrubber: Efficiency Сalculation, L/G Ratio, and Pressure Drop

t_r > 3 * t_e for safe operation.

This document outlines the methodology for designing a Venturi Scrubber system intended for hot gas cleaning. The design focuses on removing particulate matter (PM) from high-temperature flue gases using a liquid spray. The accompanying Excel calculation tool utilizes iterative algorithms to determine the throat dimensions, pressure drop, liquid-to-gas ratio (L/G), and overall collection efficiency.

If T_out_gas > 70°C , the Excel sheet should automatically highlight "Material Risk: Upgrade to SS316L."

Highlight cells in red if the flooding percentage exceeds 80%.