(Outdoor Unit), you can refer to these similar model documents which cover the same feature sets:

| Blink Pattern | Error Code | Meaning | User Solution | | :--- | :--- | :--- | :--- | | | H11 | Indoor/Outdoor communication error | Turn off breaker for 5 min. Check wiring if comfortable. | | 2 blinks | H14 | Indoor intake air sensor faulty | Call technician (needs new thermistor). | | 3 blinks | H15 | Outdoor compressor temperature sensor | Call technician. | | 4 blinks | H16 | Outdoor current transformer (CT) error | Power cycle. If persists, call pro. | | 5 blinks | H19 | Indoor fan motor locked | Turn off. Manually spin fan blade. If seized, need new motor. | | 6 blinks | H23 | Indoor pipe temperature sensor | Call technician. | | 7 blinks | H27 | Outdoor intake air sensor | Call technician. | | 8 blinks | H28 | Outdoor pipe temperature sensor | Call technician. | | 9 blinks | H97 | Outdoor fan motor error | Debris blocking outdoor fan? Remove. Else, call tech. | | Continuous fast blink | F91 | Refrigerant overcharge / Pipe blockage | Immediate professional service. |